Confidential: FUJIFILM Service Center Use Only
X-Pro1 Service Manual
3-14
<Step 4>
[Adjustment Software Start-up Screen]
Check the details and then press the [Enter] key to proceed.
<Step 5>
[Notes on using the adjustment software]
1.
Check the adjustment sequence needed when parts are
replaced.
2.
When the MAIN PWB ASSY has been replaced, carry
out the "MAIN PWB Initialize [I]" procedure before
starting the adjustment.
3.
If you have used the adjustment software, always carry
out End Setting.
4.
Refer to the Service Manual for precautions and other
detailed information on adjustment.
Check the details and then press the [Enter] key to proceed.
<Step 6>
[Jig Mode Setup Screen]
(1) When carrying out Battery Voltage Adjustment, use the
"NP-W126 Battery jig" and a regulated power supply set
to 7.2 V.
(2) For other adjustments, use the "NP-W126 Battery jig"
and supply power from the AC adapter (9V).
1. Connect the camera to the PC using the “USB cable”.
2. Use the appropriate jig according to the adjustment
options to supply power.
3. Turn the camera on while holding down the shutter
button and up key(I).
4. Check that the LED is lit green.
After completing steps 1 to 4, press the [Enter] key to
proceed.
X-PRO1 Jig Mode Setup Screen
(1) Set the Jig mode by using [NP-W126 Battery jig (7.2V)]
at Battery Voltage Adjustment.
(2) Set the Jig mode by using [DC COUPLER CP-W126 (AC Adapter (9.0V))]
at adjustments other than Battery Voltage Adjustment.
1) Connect the [USB cable].
2) Supply power to the camera using the jig
as appropriate for the adjustment details.
3) Switch camera power ON while pressing the shutter button and up key.
4) Ensure that the Led is lit.
When steps 1 to 4 are complete, press the [Enter] key on the PC.
Cautions When Using the X-Pro1_W Adjustment Software
1. Adjust as follows after replacing parts.
[F1]Battery [F4]CMOS Data [F5]Camera [F9]MOUNT
[F8]Firmware Download [F12]End Setting
[E]EVF [L]Level(Normal temperature) [H]Level(High temperature)
[I]MAIN PWB Initialize
|--------------------------------------------------------------------------------------------------------|
| Replaced Parts Adjustment Procedure
|
| MAIN PWB :
[I]
->[F9]->[L]->[F4]->[F5]->[H]->[E]->[F1]->[F12]
|
| UNIT MOUNT : [F9]->[L]->[F4]->[F5]->[H]->[E]->[F1]->[F12]
|
|--------------------------------------------------------------------------------------------------------|
2. When the MAIN PWB ASSY has been replaced, always
MAIN PWB Initialize before making any other adjustments.
3. Always run End Setting after using this adjustment software.
4. Proceed with adjustment after reading the cautions here,
and the relevant cautions noted in the Service Manual.
Press the [Enter] key to proceed to the Jig Mode Setup screen.
X-Pro1_W Adjustment Software Start-up Screen
Press the [Enter] key.
----
>
The adjustment software starts.
Revised:13.April.2012
Содержание X-Pro1
Страница 4: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 4 MEMO...
Страница 6: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 6 MEMO...
Страница 56: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 1 50 MEMO...
Страница 100: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 3 40 MEMO...
Страница 124: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 5 10 MEMO...
Страница 128: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 6 4 MEMO...
Страница 130: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 7 2 MEMO...
Страница 132: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 8 2...