3-1-2. Adjustment when replacing major parts
<Note>
Depending on the temperature inside the camera (approx. 15°C or below or 50°C or above) a "Temperature NG" error may
occur during X-Pro1 adjustment.
When a "Temperature NG" error occurs, turn the camera off and leave it for a short time before resuming the adjustments.
Check the ambient temperature also as this can influence the procedure.
Adjust the item shown by O in the table below at the part replacement of Y-10241MAIN PWB, UNIT MOUNT, CONST ASSY
FRONT and FP SHUTTER (Other part replacements need not be adjusted).
No.
Replacing parts
Adjustment item
Y-10241
MAIN PWB ASSY
UNIT MOUNT
CONST ASSY
FRONT
FP SHUTTER
0
MAIN PWB Initialize(BOOT.exe)
*1
O
1
Mount Data Write
O
O
O
2
Level Adjustment(Normal temperature)
O
O
O
3
CMOS Defect Correction
O
O
O
4
Camera
Adjustment
O O O O
5 Level
Adjustment(High
temperature) O
O
O
6 EVF
Adjustment
O
O
O
7
Battery Voltage Adjustment
O
O
O
8
Firmware Download
Do not use it until there is an instruction.
9 End
Setting
Do the end setting when you end the adjustment software when you set
the camera to the Jig mode.
* The firmware is not installed in new Y-10241MAIN PWB ASSY. When Firmware Download is not executed first, it doesn't
operate normally.
*1
When the Y-10241MAIN PWB ASSY has been replaced, always reset the MAIN PWB Initialize before making any other
adjustments.
3-2. Measuring instruments used
Measuring equipment
Remarks
Regulated power supply
For adjustment
Pattern box
PTB450F
Digital voltmeter
For Battery adjustment
PC
Used for various adjustments and operation checks (PC-AT compatible)
OS
*1
: Win 2000 SP4, XP SP2
*2
Brightness meter
LS-110 (Minolta) or equivalent
Color temperature meter Color Meter IIIF (Minolta) or equivalent
Flash meter
For adjustment and function inspection
*1: PC condition
1. Hardware
recommendation:
CPU; Pentium4 2.4GHz
or better,
Available MAIN MEMORY; 512MB
or more.
It might make an error of the adjustment when the performance of PC is low.
2.
Video Jig
must be installed.
3. Check that Microsoft .NET Framework Version 2.0 is installed.
*2: To install Microsoft .NET Framework Version 2.0 in Windows 2000 SP4, you must first install Windows Installer 3.0.
: Revised
Содержание X-Pro1
Страница 4: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 4 MEMO...
Страница 6: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 6 MEMO...
Страница 56: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 1 50 MEMO...
Страница 100: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 3 40 MEMO...
Страница 124: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 5 10 MEMO...
Страница 128: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 6 4 MEMO...
Страница 130: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 7 2 MEMO...
Страница 132: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 8 2...