5.2.4 Switching LCD screens
The types of LCD screens of the keypad are as follows.
You can operate easily according to the following program menu displayed on the screen.
Program menu
Function
DATA SET
You can check data or select a function code to be changed.
DATA CHECK
A data list is displayed.
OPR MNTR
You can monitor the current operation status of the converter.
I/O CHECK
The state of the converter and I/O terminals is displayed.
MAINTENANC
Data concerning startup of the converter or that concerning trouble occurrence or
maintenance and inspection are displayed.
LOAD FCTR
The load factor is measured.
ALM INF
The operation data immediately before occurrence of the latest alarm is displayed.
ALM CAUSE
A history of 10 past alarms and data about multiple alarms currently occurring are
displayed.
DATA COPY
A set of function codes of the converter can be saved and copied to multiple converters.
⑧
⑥
①
FUNC
DATA
:Save
(Code +
1)
≫
+PRG
≫
+PRG
FUNC
DATA
RESET
FUNC
DATA
Save
(Code +
1)
FUNC
DATA
RESET
②
③
④
⑤
FUNC
DATA
RESET
Operation
mode only
⑨
FUNC
DATA
RESET
Program menu
∧
,
∨
: Selects a
function between (1)
and (9)
0
OH1
COPY
0
Data copy
∧
,
∨
: Selects a
process
F/D: Starts copying
OH1
0
Alarm history
∧
,
∨
: Selects an alarm
OH1
0
Load factor
measurement
F/D: Starts/stops
measurement
OH1
0
CHECK DATA
∧
,
∨
: Selects a code
≫
: Selects a directory
≫
+
∧
/
∨
: Group jump
OH1
0
SET DATA
∧
,
∨
: Changes a value
STOP+
∧
/
∨
: Changes a
special value
≫
: Moves cursor
OH1
0
CAUSE
∧
,
∨
: Scrolls over
screen
OH1
0
10) Alarm history 3
9) Alarm history 2
8) Multiple alarms
7) Alarm history 1
6) DIOA input status
5) Operation status
4) I/O signals
3) Communication status
2) Action status
ALARM INFO
1) Operation status
∨
∧
OH1
0
5) DIOA input status
4) AIO Input status
3) Option terminal status
2) Operation status
I/O CHECK
1) Input signals
∨
∧
6) ROM version 2
OH1
0
5) ROM version 1
4) Communication status
3) Operation status 3
2) Operation status 2
MAINTENANCE INFO
1) Operation status 1
∨
∧
3) Operation state 3
2) Operation state 2
OH1
0
MONITOR
1) Operation state 1
∨
∧
OH1
0
Function menu
∧
,
∨
: Selects a code
≫
: Selects a directory
≫
+
∧
/
∨
: Group jump
⑦
3) Bar graph 2
Func-
tion
0
2) Bar graph 1
Operation mode
1) Operation guide
PRG
PRG
5-5
Содержание RHC-D 690V Series
Страница 8: ...Location of General Precaution and Warning Labels PWM Converter RHC D Series vi...
Страница 153: ...10 3 External Dimensions Rank 3 Converter stack RHC132S 69DE RHC160S 69DE RHC200S 69DE 10 4...
Страница 154: ...Rank 4 Converter stack RHC250S 69DE RHC280S 69DE RHC315S 69DE RHC355S 69DE RHC400S 69DE RHC450S 69DE 10 5...