Example of basic connection diagram
SX
+
+
+
+
+
+
IN
OUT
SX bus
terminator plug
SX bus terminator
plug
SX bus
expansion
cable
The maximum total length of the
SX bus expansion cable is 25 m.
P
P(+)
N
N(-)
E
E
(G)
L1/R
L2/S
L3/T
RHC-D
Inverter
OPC
-VG
7
-SX
IN
P
N
E
E
(G)
L1/R
L2/S
L3/T
RHC-D
Inverter
OPC
-VG
7
-SX
IN
P(+)
N(-)
OUT
OUT
SX bus
expansion
cable
9-21