9 - 3
INP-TN4PHAV-E
9.3
Setting of alarm latch and integrated value print-out
(1) Setup of alarm latch
• Alarm display output is retained even if alarm is OFF.
• Latch OFF and alarm OFF are printed at OFF of alarm latch function or at input of DI3 (terminal
13 to 33).
• When the alarm latch function is set to ON, instantaneous value list is not printed at input of DI3.
(2) Setup of integrated total value print
• When integrated total value print is ON, the total value only is printed at the time of printout of the
integrated list.
• Typical print
Example: Alarm latch function ON
(1) Press the SEL key to display parameter "Ink Alarm Clear".
(2) Press the SEL key while pressing the FEED key to display calibration parameter.
(3) Press the SEL key to display "Alarm latch" image.
ALARM LATCH
OFF
TOTAL PRINT
OFF
(4) Press the
key to change from OFF to ON.
(5) Finally, press the ENT key.
(6) Change Total print OFF to ON by pressing the
key.
(7) Terminate setup by pressing the ENT key.
*By pressing the DISPLAY key, the recorder is changed over to display mode.
Explanation
Explanation
Operation