6 - 6
INP-TN4PHAV-E
6.7
Over-range, under-range display and abnormal input display
In all cases, for thermocouples, resistance bulbs and DC voltage input, there is a reference range for
input signals. If input is outside preset range an 'Over' or 'Under' display is given.
Example of over/under display
Ch2 over
°
C
0.0
over
5.00
Record ON
6.00
under
3.00
Ch 5 under
°
C
Record ON
In the case of voltage input, input error display appears when the input signal line was broken or when
an over-input signal or an under-input signal was input.
Typical input error display
Ch3 Error
Error
Error
3.0
4.0
Trend record
5.0
6.0
7.0
6.8
Display and record when chart paper runs out
When there is no more chart paper, a display as follows is given and recording automatically stops.
Display of measured values and alarm monitor continue.
6.9
Display and record when the recording head ink is low
(1) A display as follows is given on the chart paper when the amount of remaining ink is low.
'Ink Out' is displayed in the display section.
Example
Ch6
123.5
°
C
Ink Out
(2) 'Ink Out' is printed on the right-hand side of the chart paper.
< Print-out color : The color of the ink whose remaining quantity is low >
Note: Ink Out' is output when the amount of ink remaining is about 10% or less and so recording
can continue for a little while even if 'Ink Out' is output.
Ch6
123.5
°
C
Chart end