Setup and installation
Warnung! Danger – electric current: Before hooking up the machine to the power supply, compare the
specifications on the data plate with those of the electrical network. Only hook up the machine if the two
sets of data correspond to each other. The electrical outlet must have the appropriate socket (for a three
phase alternating current motor, CEE).
The machine‘s power cable is delivered with an open
cable end, i.e. without a plug.
The operator is responsible for fitting the machine‘s
power cable with a suitable plug in accordance with any
country-specific regulations.
1.
Connect the plug to the power supply.
2.
Switch on and let the machine run briefly.
3.
While the motor is running, check its direction of
rotation.
4.
Should a change in the direction of rotation be nec-
essary, switch the two phases on the power cable.
Cross cut table and backup fuse
Motor power
4 kW
5,5 kW
7,35 kW
Mains voltage 230 ± 10% V
Cable cross-sectional area min.
2,5 mm²
2,5 mm²
4,0 mm²
Backup fuse
20 A
35 A
35 A
Mains voltage 400 ± 10% V
Cable cross-sectional area min.
2,5 mm²
2,5 mm²
4,0 mm²
Backup fuse
16 A
16 A
20 A
Warnung! Danger – electric current: Work on electrical fittings may only be carried out by qualified per-
sonnel and in strict observance of the safety instructions.
Attention: Do not open the switch box of the machine without the express consent of the Format-4 service
department. Violating this stipulation shall render the right to make claims under the warranty null and
void.
Characteristics of electrical connections:
• The machine must be earthed with electrical conduc-
tors.
• The voltage fluctuations in the mains supply may not
exceed ±10%.
• Safeguarding 16 A, Triggering characteristic C.
• Power supply cable at least 5x2,5 (Three-phase al-
7.5 Electrical connection
ternating current motor) or 3x2,5 (Alternating-current
motor).
• The power supply cable must be protected against
damage (e.g. armoured conduit).
• The power supply cable must be laid in such a way
that it does not overbend or chafe and there is no
risk of tripping over it.
5.
Push the parts together.
6.
Tighten the thumb screw.
7.
The stranded wires are connected electrically via the
fit clamp connection.
!
Section
"
Seal
#
Thumb screw
Fig. 36: Potential-free contact