Panel Saws
kappa 30/kappa 40
Panel Saw
Kappa 30 / kappa 40
Setup and installation
7.4 Chip extraction
The machine has to be connected to a dust extractor.
Requirements for the vacuum system and hoses:
Attention! The vacuum hoses must be flame retardant. Only use original FORMAT-4 vacuum hoses !
Overhead saw guard
Saw guard
Outlet size Ø (Unit)
120 mm
120 mm
Outlet size Ø (Overhead saw guard and saw guard)
80 mm
50 mm
Air speed, min.
20 m/s
20 m/s
Vacuum, min.
1200 Pa
1400 Pa
Volume flow, min. (at 20 m/s)
1450 m3/h
1110 m3/h
Connecting the dust extractor to a potential-free contact
(Option).
The dust extractor can be connected via the potential-free
contact.
1.
Pinch off the stranded wires flushly.
2.
Unscrew the thumb screw.
3.
Thread the thumb screw and seal over the cable.
4.
Insert the stranded wires into the disconnections „1“
and „2“.
!
Potential-free contact
Fig. 35: Potential-free contact
• The vacuum system must produce the required vacu-
um and air flow.
• Connect the vacuum system to the machine in such a
way that they run in unison.
• The vacuum hoses must be electrically conductive
and grounded to prevent electrostatic loading.
Before putting the machine into operation for the first
time, inspect it for defects.
39
!