LESSON 3: POWERTRAIN
APPS Pedal Travel
The driver actuates the accelerator pedal in the usual manner. The APPS is not adjustable. No adjustment is
required because pedal position and relative movement is calculated within the PCM.
•
APPS 1 voltage is in the range of 4.10 to 0.95 volts:
– 4.10 volts with the pedal at rest.
– 0.95 volts with the pedal fully depressed.
•
APPS 1 is used as the driver demand indicator:
– The PCM uses APPS1 at all times unless APPS1 has failed.
•
APPS 2 voltage is in the range of 1.51 to 3.90 volts:
– 1.51 volts with the pedal at rest.
– 3.90 volts with the pedal fully depressed.
•
APPS 3 voltage is in the range of 0.95 to 3.34 volts:
– 0.95 volts with the pedal at rest.
– 3.34 volts with the pedal fully depressed.
2004 Explorer/Mountaineer New Model Technician Training
12-AUG-03
3-19