Operating Manual BKS309.W.M
22.02.2019
28
Setting: [Manual]
Description:
The controller is set to manual mode (default)
Setting: [Auto]
Description:
The controller is set to automatic mode.
Setting: [Last
Set]
Description:
The controller is set to the mode that was set before the system has
been shut down.
Leaving the automatic mode [Auto
→
Man]
Description:
This parameter determines the behavior of the controller when you
leave the automatic mode.
Setting: [Manual]
Description:
The control is determined and the controller switches to manual
mode. (Default)
Setting: [Center]
Description:
The control is determined and the steering frame/actuator moves to
the center position. (Default)
Home position of the actuator [Home Pos]
Description:
This parameter determines the home position of the actuator in
retracted position. This position acts as stop and will never be
crossed. Refer to page 17.
Range:
0.0 to
300.0
Default:
0.0
Increment:
0.1
unit: [ mm]
Requirement:
This parameter is only accessible if an actuator of the FMS
winderGLIDE series is installed.
Center position of the actuator [CentrPos]
Description:
This parameter determines the center position of the actuator. If you
press
the actuator approaches this position automatically.
Refer to page 17
.
Range:
0.0 to
300.0
Default:
62.5
4)
Increment:
0.1
unit: [ mm]
Requirement:
4)
The default setting is depending on the type (stroke) of the
installed actuator. This parameter is only accessible if an actuator of
the FMS winderGLIDE series is installed.
Содержание BKS309.W.M
Страница 38: ...Operating Manual BKS309 W M 22 02 2019 38 Illustration 18 Virtual operating panel...
Страница 39: ...Operating Manual BKS309 W M 22 02 2019 39 Illustration 19 List of parameters Illustration 20 Traverse settings...
Страница 40: ...Operating Manual BKS309 W M 22 02 2019 40 Illustration 21 Traverse types Illustration 22 Ethernet settings...
Страница 47: ...Operating Manual BKS309 W M 22 02 2019 47...