Operating Manual BKS309.W.M
22.02.2019
32
9
System parameters
Warning
All system parameters have been pre-set individually per system. These settings should
only be changed in compliance with the FMS Service. Non-authorized changes can lead to
malfunctions and cause damage to the system or the machine.
To enter the mode for changing the system parameters you have to press the keys
and
at the same time and hold it for 3 sec. The LED above
switches on and the first
parameter name is displayed in the LCD.
System parameters are not affected by the reset to default settings.
Adjustment of the reference value [Offset><]
Description:
Choose this value to adjust the reference value oft he steering
frame/actuator.
Range: -5.00
to
+5.00
Default: 0.00
Increment: 0.01
unit: [mm]
Type of positioning system [PosDetect]
Description:
This parameter determines the type of positioning system of the
actuator drive. A modification of this parameter requires a re-start of
the controller.
Typ: [Potentio]
Description:
A potentiometer is used to detect the traveling limits and the center
position of the actuator.
If you have installed an actuator of the FMS winderGLIDE series this
value is set automatically.
Typ: [One
Hall]
Description:
A single hall sensor is used to detect the position of the drive.
Typ: [Two
Hall]
Description:
Two hall sensors are used to detect the position of the drive.
(Default)
Содержание BKS309.W.M
Страница 38: ...Operating Manual BKS309 W M 22 02 2019 38 Illustration 18 Virtual operating panel...
Страница 39: ...Operating Manual BKS309 W M 22 02 2019 39 Illustration 19 List of parameters Illustration 20 Traverse settings...
Страница 40: ...Operating Manual BKS309 W M 22 02 2019 40 Illustration 21 Traverse types Illustration 22 Ethernet settings...
Страница 47: ...Operating Manual BKS309 W M 22 02 2019 47...