Operating Manual BKS309.W.M
22.02.2019
26
Description:
A rising edge on the input triggers this function and the stored
position point is approached.
Setting: [Disabled]
Description:
This function disables the selected input.
Setting:
Move traverse to right [MoveTvR]
Description:
This level controlled function triggers the movement of the
connected traverse to the right. The traverse moves as long as the
input signal is equal to the input voltage. If the level decreases to
zero the movement stops.
If two traverses are installed and configured, both will move to the
right in parallel.
Setting:
Move traverse to right [MoveTvL]
Description:
This level controlled function triggers the movement of the
connected traverse to the left. The traverse moves as long as the
input signal is equal to the input voltage. If the level decreases to
zero the movement stops.
If two traverses are installed and configured, both will move to the
right in parallel.
DLS
Purpose:
If you use a DLS2 sensor, you have to set the correct installation
direction. You can only connect one DLS2 sensor.
The user can choose between three settings.
Setting:
[none]
Purpose:
There is no DLS2 sensor connected. Standard setting.
Setting:
[left]
Purpose:
The DLS2 sensor is installed on the left-hand side (in direction of the
moving web)
Setting:
[right]
Purpose:
The DLS2 sensor is installed on the right-hand side (in direction of
the moving web)
[Password]
Description:
You can protect the access to the controller settings with a
password. The password cannot be changed and is set to 3231.
Setting: [No]
Description
Password protection disabled (default)
Содержание BKS309.W.M
Страница 38: ...Operating Manual BKS309 W M 22 02 2019 38 Illustration 18 Virtual operating panel...
Страница 39: ...Operating Manual BKS309 W M 22 02 2019 39 Illustration 19 List of parameters Illustration 20 Traverse settings...
Страница 40: ...Operating Manual BKS309 W M 22 02 2019 40 Illustration 21 Traverse types Illustration 22 Ethernet settings...
Страница 47: ...Operating Manual BKS309 W M 22 02 2019 47...