Operating Manual BKS309.W.M
22.02.2019
24
Set relay outputs 1 and 2 [Relay 1] und [Relay 2]
Description:
This parameter sets the function behind the relay outputs.
Setting:
Middle position found [MidSenso]
Description:
the relay is activated as soon as the web edge is detected in center
the sensor area. (Default Relay 1)
Setting:
Web detected [MatFound]
Description:
They relay is activated as soon as the web edge is detected in the
senor area. (Default Relay 2)
Setting:
Automatic mode and web detected [Auto&Mat]
Description:
The relay is activated as soon as the web edge is detected in the
sensor area and the controller is set to automatic mode.
Setting:
Automatic mode and no web [Aut&Miss]
Description:
The relay is activated as soon as no web edge is detected in the
sensor area and the controller is set to automatic mode.
Setting:
Automatic mode [Auto]
Description:
The relay is activated as soon as the controller is set to automatic
mode.
Setting:
Actuator in center position [Centre]
Description:
The relay is activated as soon as the actuator is in center position.
Setting: [Disabled]
Description:
The relay function is disabled.
Settings of digital inputs 1, 2, 3 and 4 [Input 1] to [Input 4]
Description:
The controller has 4 digital inputs. These inputs are either level or
pulse controlled. The pulse controlled inputs are activated with an
impulse of min. 100ms. The level controlled inputs are activated
with a rising edge. It stays active as long as the signal is received.
The input is deactivated as soon as the signal drops out.
Note:
Any function that you have assigned to an input channel will have a
direct impact on the manual operation of the control panel. Level
controlled parameters will not be visible in the respective menu and
keys will be disable, e.g. when you assign "automatic/manual mode"
key to an input, the key on the panel will be disabled.
Setting:
Pulse controlled manual/automatic mode [Edge
→
Aut]
Description:
The controller switches from manual to automatic mode or vice
versa. (Default for Input 1)
Setting:
Level controlled manual/automatic mode [Lv
→
Auto]
Содержание BKS309.W.M
Страница 38: ...Operating Manual BKS309 W M 22 02 2019 38 Illustration 18 Virtual operating panel...
Страница 39: ...Operating Manual BKS309 W M 22 02 2019 39 Illustration 19 List of parameters Illustration 20 Traverse settings...
Страница 40: ...Operating Manual BKS309 W M 22 02 2019 40 Illustration 21 Traverse types Illustration 22 Ethernet settings...
Страница 47: ...Operating Manual BKS309 W M 22 02 2019 47...