Operating Manual BKS309.W.M
22.02.2019
25
Description:
The controller switches from manual to automatic mode or vice
versa.
Setting:
Move actuator to center position [Centre]
Description:
This input triggers the movement of the actuator to the center
position. (Default for Input 2).This input is level controlled
Setting:
Decrease reference value or drive to left [-Ref/
←
]
Description:
Depending on the operating mode two settings are possible. If the
controller is set to manual mode the steering frame moves to the
left side of the installed actuator retracts. If the controller is set to
automatic mode the reference value is increased in increments of
0.1 mm. (default for Input 3). This input is pulse controlled.
Setting:
Increase reference value or drive to right [+Ref/
→
]
Description:
Depending on the operating mode two settings are possible. If the
controller is set to manual mode the steering frame moves to the
right side of the installed actuator extends. If the controller is set to
automatic mode the reference value is increased in increments of
0.1 mm. (default for Input 4). This input is pulse controlled.
Setting:
Lock steering frame [Lock]
Description:
the steering frame is locked as soon as the level rises. The Input
[Lock], operating mode [Auto] and the parameter [Auto
Man] are
partly dependent on each other. The interaction is compiled in the
following table.
Dig.inp.
Lock
Mode
Auto.
Parameter
Auto
→
Man
Function
0
Not active
Center
Move to center position
0 active
Automatic
mode
1
Not active
Manual
Stops at current position
1
Not active
Center
Move to center position
1
active
--
Stops at current position
Setting:
Reset the reference value [ResetRef]
Description:
this function is level controlled and resets the reference value to zero
as soon as a positive edge drops in.
Setting:
Retract traverses [Retract]
Description:
This pulse controlled function retracts all installed traverses.
Setting:
Automatic traverse movement to detect web [Detect]
Description:
This level controlled function triggers the automatic search for the
web. The function is active as long as the input signal is equal to the
input voltage. If the level decreases to zero the function is
deactivated.
Setting:
Reposition traverse [Goto Pos]
Содержание BKS309.W.M