6 Mounting
FLUXUS F502TE
6.2 Transducers
37
UMFLUXUS_F502TEV1-5EN, 2020-05-29
Ratchet clasp
• Insert the tension strap into the tension strap clamp (2) and the metal spring (see Fig. 6.21 and Fig. 6.24). The metal
spring does not have to be mounted on:
– steel pipes
– pipes with an outer pipe diameter < 80 mm
– pipes that are not subjected to significant temperature fluctuations
• Position the ratchet clasp, tension strap clamp (2) and metal spring (if necessary) on the pipe.
• Position the metal spring opposite to the tension strap clamp.
• Place the tension strap around the pipe and pass it through the slot of the clasp screw (see Fig. 6.25).
• Tighten the tension strap.
• Cut off the protruding tension strap (see Fig. 6.25).
• Tighten the clasp screw.
• Tighten the nut of the tension strap clamp (2), but not too firmly in order not to damage the tension strap (see Fig. 6.21).
Fig. 6.22: Tension strap with band clamp clasp
Fig. 6.23: Tension strap with quick release clasp
and metal spring
1 – clasp screw
1 – clasp screw
2 – metal spring
Caution!
The edge of the tension strap is very sharp.
Risk of injury!
→ Debur sharp edges.
→ Wear the required personal protective equipment.
→ Observe the applicable rules.
Notice!
In order to release the screw and the tension strap, press the lever down (see Fig. 6.18).
Fig. 6.24: Tension strap with metal spring and clamp
1 – metal spring
2 – tension strap clamp
1
2
1
1
2
Содержание FLUXUS F502BT
Страница 1: ...FLUXUS F502TE UMFLUXUS_F502TEV1 5EN Operating instruction...
Страница 6: ...Table of contents FLUXUS F502TE 2020 05 29 UMFLUXUSF502TEV1 5EN 6...
Страница 144: ...19 Thermal energy rate measurement 19 4 Steam in inlet FLUXUS F502TE 2020 05 29 UMFLUXUS_F502TEV1 5EN 144...
Страница 160: ...Annex D Conformity declarations FLUXUS F502TE 2020 05 29 UMFLUXUS_F502TEV1 5EN 160 D Conformity declarations...
Страница 161: ......
Страница 162: ......