17 SuperUser mode
FLUXUS F502TE
17.1 Activation/deactivation
121
UMFLUXUS_F502TEV1-5EN, 2020-05-29
17
SuperUser mode
The SuperUser mode allows an advanced diagnostic of signals and measured values as well as the definition of additional
parameters adapted to the measuring point, in order to achieve better measured values or for experimental work. Special
features of the SuperUser mode are:
• Default settings will not be used.
• There are no plausibility tests during the parameter entry.
• It is not checked whether the entered parameters are within the limits given by physical laws and technical data.
• The cut-off flow is not activated.
• A number of sound paths has to be entered.
Some menu items that are not visible in the normal mode are displayed.
17.1
Activation/deactivation
• Enter the HotCode
071049
(see section 8.4).
• Press ENTER.
It is displayed that the SuperUser mode is activated.
• Press ENTER. The main menu will be displayed.
• Enter the HotCode
071049
again to deactivate the SuperUser mode.
It is displayed that the SuperUser mode is deactivated.
• Press ENTER. The main menu will be displayed.
17.2
Definition of the flow parameters
In the SuperUser mode, it is possible to define some flow parameters (profile bounds, correction of the flow velocity) for
the specific application or measuring point.
• Select the menu item
Special Funct.\SYSTEM settings\Measuring\Calibrat. data
.
• Press ENTER.
17.2.1
Profile bounds
• Select
user
to define the profile bounds. If
factory
is selected, the default profile bounds will be used and the menu
item
Calibration
will be displayed.
• Press ENTER.
Notice!
The SuperUser mode is intended for experienced users with advanced application knowledge. Changed parameters
can affect the normal measuring mode and lead to wrong measured values or to a measurement failure when a new
measuring point is set up.
SUPERUSER MODE\IS ACTIVE NOW
SUPERUSER MODE\IS PASSIVE NOW
Notice!
Some of the defined parameters remain activated after the deactivation of the SuperUser mode.
Special Funct.\SYSTEM settings\Measuring\Calibrat. data
Special Funct.\...\Calibrat. data\...\Profile bounds
Содержание FLUXUS F502BT
Страница 1: ...FLUXUS F502TE UMFLUXUS_F502TEV1 5EN Operating instruction...
Страница 6: ...Table of contents FLUXUS F502TE 2020 05 29 UMFLUXUSF502TEV1 5EN 6...
Страница 144: ...19 Thermal energy rate measurement 19 4 Steam in inlet FLUXUS F502TE 2020 05 29 UMFLUXUS_F502TEV1 5EN 144...
Страница 160: ...Annex D Conformity declarations FLUXUS F502TE 2020 05 29 UMFLUXUS_F502TEV1 5EN 160 D Conformity declarations...
Страница 161: ......
Страница 162: ......