3 General principles
FLUXUS F502TE
3.3 Acoustic penetration
15
UMFLUXUS_F502TEV1-5EN, 2020-05-29
3.3
Acoustic penetration
The pipe has to be acoustically penetrable at the measuring point. The acoustic penetration is given when pipe and fluid
do not attenuate the sound signal so strongly that it is completely absorbed before reaching the second transducer.
The attenuation caused by the pipe and the fluid depends on:
• kinematic viscosity of the fluid
• proportion of gas bubbles and solids in the fluid
• deposits on the inner pipe wall
• pipe material
The following requirements have to be met at the measuring point:
• the pipe is always completely filled
• no solid deposits in the pipe
• no bubble formation in the pipe
Observe the following notes on the selection of the measuring point:
Horizontal pipe
Select a measuring point where the transducers can be mounted laterally on the pipe, allowing the sound waves to propa
-
gate horizontally in the pipe. Thus, solids on the bottom of the pipe or gas bubbles in the pipe's upper part are prevented
from influencing the propagation of the signal (see Fig. 3.7 and Fig. 3.8).
Vertical pipe
Select the measuring point at a pipe section where the fluid flows upward. The pipe has to be completely filled (see Fig. 3.9
and Fig. 3.10).
Free inlet or outlet pipe section
Select the measuring point at a pipe section where the pipe cannot run empty (see Fig. 3.11 and Fig. 3.12).
Notice!
Even bubble-free fluids can form gas bubbles when the fluid expands, e.g., before pumps and after great cross-section
extensions.
Fig. 3.7:
Recommended transducer mounting position
Fig. 3.8:
Disadvantageous transducer mounting position
Fig. 3.9:
Recommended transducer mounting position
Fig. 3.10: Disadvantageous transducer mounting position
Содержание FLUXUS F502BT
Страница 1: ...FLUXUS F502TE UMFLUXUS_F502TEV1 5EN Operating instruction...
Страница 6: ...Table of contents FLUXUS F502TE 2020 05 29 UMFLUXUSF502TEV1 5EN 6...
Страница 144: ...19 Thermal energy rate measurement 19 4 Steam in inlet FLUXUS F502TE 2020 05 29 UMFLUXUS_F502TEV1 5EN 144...
Страница 160: ...Annex D Conformity declarations FLUXUS F502TE 2020 05 29 UMFLUXUS_F502TEV1 5EN 160 D Conformity declarations...
Страница 161: ......
Страница 162: ......