LED LIGHTING INSTALLATION
Step 11:
Remove the RGB control box from the components parts carton. Find a suitable location within a close
proximity of the fireplace for convenience of operation and mount the control box upright and level as shown in Fig. 26,
page 21. Use Figs 24 & 25 for dimensional reference. The fireplace is supplied with 10-feet of wiring for the RGB control
box (switches and dimmer) installation.
Note:
If desired, you can purchase 10-feet wire extensions in the accessories
section that will enable you to move the RGB control box up to 50-feet away from the fireplace.
CAUTION:
Ensure all
switches are in the OFF position.
“I” indicates ignite/ON and “O” indicates OFF.
Learn button does not apply.
Step 12:
Remove the four (4) outer screws from each corner inside the cover plate and lift off. See Fig. 24. This will
expose the mounting plate. See Fig. 25.
CAUTION:
Do not remove the two center screws from the cover plate. This will
release the entire switch box wiring from inside the junction box and make it difficult to reinstall.
Take note of the 8-PIN (77160) and 6-PIN (77111) wire connectors. These are labeled LED lights (6-PIN) and Control
Module (8-PIN) connections. These will be the final connection to the fireplace and crucial to the operation.
Step 13:
Find a desired location to mount the RGB control box. Cut a 6” wide x 5 ½” tall hole into the cement board. See
dotted line in Fig. 25. Mount the RGB control box.
Note:
The wires from the switches can be removed for easier
installation, if needed. Ensure to match the wires with the labels for each switch when reattaching.
Step 14:
Remove the 8-PIN module wire harness (77161) from the components part box. Locate the 8-PIN male
connector from the valve box (under the fireplace) and connect it to the 8-PIN female end of the wire harness.
Connectors only attach one way; press together until it snap locks into place. See Fig. 26, page 21 for details.
Step 15:
Feed the other end of the wire harness through the square access hole underneath the fireplace and pass the
GFCI box, outside the fireplace to the RGB control box and connect. Connectors only attach one way; press together
until it snap locks into place.
Step 16:
Locate the two ¼” male terminals from the valve box and connect the AF-4000ADP24 adapter. Plug the 7.5VDC
adapter into the 120VAC GFCI box.
Step 17:
Locate the 6-PIN wire harness (77111) for the LED lights and feed the wire harness up to the RGB
control box and attach. Connectors only attach one way; press together until it snap locks into place. See Fig. 26, pg 21.
Step 18:
Plug 12-volt adapter (77120) into the 120VAC GFCI outlet double gang junction box described on page 16.
Step 19:
Plug 77160 into 77161 to connect the control module to RGB control box then connect the AF-4000ADP48EXT
to the AF-4000ADP24 and plug it into the 120VAC GFCI outlet double gang junction box. See Fig. 26, pg 21 for reference.
Fig. 24
RGB control box with 8 ¾” x 8 ¾” cover plate.
RGB DIMMER
Cover Plate Surrounding Switch Plate
Remove screws to mount switch plate
Remove screws to mount switch plate
LED
ON/OFF
ON/OFF
LOW
HIGH
LEARN
CONT.
PILOT
RGB DIMMER
Mounting plate under switch cover
LED
ON/OFF
ON/OFF
LOW
HIGH
LEARN
CONT.
PILOT
5-5/8”
(143mm)
5-5/8”
(143mm)
Fig. 25