Kalea Bay LED Outdoor Fireplace
REV. B Page 32
Model
Main Burner
Orifice
Low Rate Set
Screw
OFP-36LECO-LPK
OAS-LPR52
ECO-LSS-52
OFP-48LECO-LPK
OAS-LPR48
ECO-LSS-46
OFP-60LECO-LPK
OAS-LPR44
ECO-LSS-42
OFP-72LECO-LPK
OAS-LPR42
ECO-LSS-35
This kit will properly convert the outdoor fireplace to LP gas. Kit contents are: (1) OAS-LP# (Brass orifice) and
(1) ECO-LSS# (Brass low rate set screw), (1) LP Conversion label (placed next to blank space on rating label,
(1) Installation instruction
Fig. 1.
Contents of kit
Step 1
: Turn OFF the gas supply to the outdoor
fireplace and disconnect any electrical power.
Step 2
: Remove the burner pan from the fireplace to
enable conversion access. See installation manual if
necessary.
Step 3
. Disconnect the flex line at the main burner
orifice. Then remove the orifice and flared fitting from the
orifice. Re-tape the flared fitting with the new OAS-LP
orifice per Table 1. Ensure to use gas rated Teflon tape
around the threads or pipe compound. Check for leaks
after conversion is complete.
Fig. 2
Changing main burner orifice
Step 4:
Locate the gas regulator the opposite side of the
valve box. Using a regular size flat bladed screwdriver
remove the aluminum cap and washer from the regulator.
See Fig. 2.
Table 1
Reference information
Fig. 4
Regulator stem shown in NG setting
NOTE:
The plastic stem has a marking on it with an arrow.
Look carefully on the stem, it may be difficult to read.
The gas type is determined with the arrow pointing at the
aluminum cap as seen in Figs. 4 and 5.
Step 5:
On the underneath side of the aluminum cap is a
plastic stem. Using a 6mm wrench remove the stem,
unscrew the stem (counter-clockwise), turn it over and
install the opposite end back into the cap. See Fig. 4.
Fig. 3
Regulator
cap location
NATURAL GAS TO LP GAS CONVERSION
Main Burner Orifice
(OAS-LP#)
Low Rate Set
Screw
(ECO-LSS-#)
Label
This fireplace was
converted to LP gas by
__________________
Date: ______________