Kalea Bay LED Outdoor Fireplace
REV. B Page 5
INSTALLATION PRECAUTIONS
1.
These fireplaces are designed for outdoor use only. Not approved for any indoor use.
2. Determine which fireplace you are preparing to install, single-sided or see-through. (Refer to page 11 or 14).
3.
This fireplace is not a “load bearing” fireplace. All finishing materials must be supported by the surrounding
structure and not rely on the fireplace itself.
4. Fireplaces create high temperatures, it is very important to have any combustibles at a safe distance. See pages 11
for a single sided installation or page 14 for see-through installation.
5. Fireplace should never be left unattended while in operation. It should always be a safe distance from all trees and
combustible landscape materials.
6. The fireplace must be installed on a flat, level, stable, non-combustible surface.
Exception
: It is permissible
to place one layer of ½” cement board underneath the entire fireplace, then it may sit on a flat, level, stable,
combustible surface. Drainage is critical to ensure that water does not damage gas valve and components.
Never install the fireplace below grade.
7.
CAUTION
: A minimum of 18 square inches of cross ventilation (per side) is required to keep the inside of the
enclosure dry. Install the supplied VENT-KIT-6x12SS approximately 3 to 4 inches from the floor centered on each end
of the fireplace (See Fig. 3, page 6).
8. Only non-combustible materials (i.e. metal studs and cement board) should come in direct contact with any part
of the fireplace. Underneath area should be non-combustible or a flat level combustible surface according to the
clearances specified in this manual. Bend out nailing flanges on ends of fireplace and secure to metal studs.
9.
Hearth Extension:
A hearth extension is not required with this fireplace. Any hearth extension used is for
appearance only and does not have to conform to a standard hearth extension installation requirements.
10. This fireplace is designed to have glass media covering the burner trough, so the burner tube is not visible.
Media is
NOT
provided and must be purchased separately. When installing media use minimum of ½” to ¾”
diameter Firegear Outdoors glass to fill the burner trough. After the burner trough is covered you are permitted to fill
the remaining area in the burner pan.
DO NOT COVER THE IGNITION HOOD WITH ANY ROCK OR MEDIA.
See
Figs. 34 - 36 on pages 25 and 26 for details.
11. Do not use media that will absorb moisture over time and will not release this moisture quickly. Moisture can boil in
this media and can rapidly break apart and cause property damage or personal injury.
12. Never leave any other combustible material on top of the fireplace. This could cause unsafe operation of this system
and damage to the component that will not be covered under our warranty.
13. It is recommended to wear gloves when moving the fireplace into position and watch for sharp edges when handling
the fireplace.
14. We recommend using ¾” black iron pipe; however please refer to the NFPA54 (National Fuel Gas Code) for proper
pipe sizing when exceeding 20-feet in length for fireplaces .
15. Follow the local code requirements for the gas type being used. This fireplace should be installed in accordance with
local codes and ordinances or in the absence of local codes, with the latest National Fuel Gas Code, ANSI Z223.1
NFPA54 or CSA B149.1, Natural and Propane Installation Code in Canada.
16. This appliance must be electrically grounded in accordance with the local codes, or in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70; or the Canadian Electrical Code, CSA C22.1, if applicable.
17. Gas lines and fittings must be installed into the non-combustible structure. All gas connections must be leak tested
before installation of the fireplace. Leak detection is required before regular use of the fireplace.
18.
LED LIGHTING
: LED lighting must be installed before finishing materials are completed on this fireplace. Ensure
electricity is run before the fireplace is installed. See pages 16-23. Ensure you follow the local codes per your
installation.