Kalea Bay LED Outdoor Fireplace
REV. B Page 8
FRAMING FIREPLACE
Disclaimer:
Btu listings are based on 7.0”WC (1.74 kPa) for Natural Gas at inlet side of gas regulator. Flex line
sizing and proper gas pipe sizing can affect Btu’s. As a result, your Btu’s may vary slightly from Table 1 specifications.
NOTE:
These fireplaces come shipped as Natural Gas models only. There is an LP conversion kit available as an
accessory. Ensure you order the specific conversion kit for your model fireplace. Table 1 shows the applicable information
if converting to Liquid Propane (LP) gas. See page 32.
IMPORTANT:
It is permissible to reverse the burner pan in the field to enable a closer gas line connection if necessary.
SPECIFICATIONS
Fig. 4
The fireplace ships on a wooden skid. Remove the
screws as shown and lift fireplace off of skid.
Note:
Number of screws vary with model size.
Table 1.
Fireplace specifications and conversion kits.
NG Models:
NG
Factory
Orifice
NG Btu’s
High
NG Btu’s
Low
NG Low
Rate
Screw
LP
Conversion Kit
LP Factory
Orifice
LP Low Rate
Screw
OFP-36LECO-NLED
#41
31,000
(9.08 kW)
18,500
(5.42 kW)
#44
OFP-36LECO-LPK
OAS-LP52
ECO-LSS-52
OFP-48LECO-NLED
#32
43,500
(12.74 kW)
24,500
(5.42 kW)
#34
OFP-48LECO-LPK
OAS-LP48
ECO-LSS-46
OFP-60LECO-NLED
#30
50,000
(14.65 kW)
36,000
(7.18kW)
#27
OFP-60LECO-LPK
OAS-LP44
ECO-LSS-42
OFP-72LECO-NLED
#25
65,000
(19.00 kW)
42,000
(12.30 kW)
#18
OFP-72LECO-LPK
OAS-LP42
ECO-LSS-35
Table 2
Gas Pressures
Pressure
NG
LP
Min. Inlet
5.0” WC (1.24kPa)
10.5” WC (2.61 kPa)
Max. Inlet
10.5” WC (2.61kPa) 13.0” WC (3.23 kPa)
Normal Inlet 7.0” WC (1.74 kPa) 11.0” WC (2.73 kPa)
Manifold
4.0”WC (.99 kPa)
10.0”WC (2.48 kPa)