Festo — MSE6-C2M — 2022-08b
Malfunctions
93
Error
channel
Meaning
Remedy
Activation
parameter
m = module
number 0
Error number 0, no error or end of a message status
–
–
–
Cannot
be deactivated
Error number 2, short circuit/overload
Em.3
Short circuit/
overload sensor
supply
24V DC U
SEN
–
Clear short circuit/overload, check connected
sensors if necessary.
–
Depending on the set parameter value, behav-
iour according to SCS, Pm.27.6:
–
Setting 1 = switch on again: sensor supply
voltage is automatically switched on again
after elimination of short-circuit/overload.
–
Setting 0 = leave switched off. Switching
on the sensor supply voltage again: power
off/on necessary.
or
Change parameter response after SCS,
Pm.27.6 auf 1 = switch on again
Pm.0.0
Monitoring
Short circuit/
overload
Sensor supply
Am.0
Short circuit/
overload at elec-
trical outputs on
at least one
electrical output
–
Clear short-circuit/overload, check connected
actuators if necessary. The number of the
faulty channel is signalled in the Em.3.14, DO0
and Em.3.15 inputs, DO1.
–
Depending on the set behaviour according to
SCO parameter, Pm.27.7:
–
Setting 1 = switch on again: output is auto-
matically switched on again after elimina-
tion of short-circuit/overload.
–
Setting 0 = leave off: output remains reset
to 0. Switch the output back on: set the
output to 0 and then back to 1.
or
Change behaviour after SCO parameter,
Pm.27.7, to 1 = switch on again.
Pm.0.1
Monitoring
Short circuit/
overload
Electrical out-
puts