Festo — MSE6-C2M — 2022-08b
Functions
37
Data format of input word sign + 15 bits, right-justified
D15
D14
D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
VZ
B14
B13 B12 B11 B10 B9
B8
B7
B6
B5
B4
B3
B2
B1
B0
MSB
LSB
Abbreviations used
VZ
Prefix
B0 … B14
Pressure change value
DO … D15
16-bit input data field
MSB/LSB
Most significant bit/least significant bit
Tab. 15: Data format of input word Em.5/Em.6 “Pressure change”
5.2.2.8
Input word Em.3 module status
In the input Em.3 status information and module status information are shown.
Data format of input word 16 bits, right-justified
D15
D14
D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
B15
B14
B13 B12 B11 B10 B9
B8
B7
B6
B5
B4
B3
B2
B1
B0
MSB
LSB
Abbreviations used
B0
Status of shut-off valve
B1
Monitoring sensor supply
B2
Status of electrical input 0
B3
Status of electrical input 1
B4, B5
Status Q_low-Timer
B6
Monitoring of lower critical limit pressure P2
B7
Measurement of impulse consumption VC
B8 … B11
Module status
B12
Status of consumption V0
B13
Status of consumption V1
B14
Monitoring of electrical output 0
B15
Monitoring of electrical output 1
D0 … D15
16 bit input data field
MSB/LSB
Most significant bit/least significant bit
Tab. 16: Data format of the input word Em.3 module status