Festo — MSE6-C2M — 2022-08b
Technical data
101
MSE6-C2M
Residual pressure
[bar]
<
1
[psi]
<
14.5
1) % FS = percentage of the measurement value range end value (full scale)
2) Typical accuracy under nominal conditions (0.6 MPa (6 bar, 87.02 psi), 23 °C and horizontal mounting position)
3) measured at ambient temperature 23 °C ± 5 °C and temperature of medium 18 °C ± 5 °C
Tab. 86: Technical data, pneumatic
12.3
Technical data, electrical
MSE6-C2M
Operating voltage supply for electronics and sensors, U
El/Sen
Nominal voltage
[V DC]
24 ± 25 %
Nominal voltage range
[V DC]
18 … 30
Intrinsic current consump-
tion at 24 V
[mA]
Max. 350
Additional current consump-
tion via sensor supply at
electrical inputs
[mA]
Max. 1000
Only MSE6-...-M:
Additional current consump-
tion via connected modules
at extension interface
Description of the connected modules,
MSE6-D2M, CPX-I/O modules
Residual ripple
[%]
£
10, within the nominal voltage range
Cable length
[m]
Max. 30
Load voltage supply for actuator technology, U
Out/A
Nominal voltage
[V DC]
24 – 10 %/+ 20 %
Nominal voltage range
[V DC]
21.6 … 28.8
Intrinsic current consump-
tion at 24 V
[mA]
Max. 260
Additional current consump-
tion via load current at elec-
trical outputs
[mA]
Max. 1000
Only MSE6...-M: additional
current consumption via
connected modules at exten-
sion interface
è
documentation of the connected modules,
MSE6-D2M, CPX-I/O modules
Residual ripple
[%]
£
10, within the nominal voltage range
Cable length
[m]
Max. 30