Connector Pin Assignment
CAN-CBX-THERMO
Manual • Doc.-No.: C.3034.21 / Rev. 1.2
Page 33 of 123
5.3 Thermocouple Interface (X500)
Device’s socket:
Phoenix Contact MC 1,5/12-GF-3,81
Line connector:
Phoenix Contact MC 1,5/12-STF-3,81, screw connection
Phoenix Contact order No.: 1827800 (included in delivery)
For conductor connection and conductor cross section see page 34.
Pin Position:
Pin Assignment:
Signal
Pin
Description
S4+
1
Interface thermocouple 4
Shield
2
S4-
3
S3+
4
Interface thermocouple 3
Shield
5
S3-
6
S2+
7
Interface thermocouple 2
Shield
8
S2-
9
S1+
10
Interface thermocouple 1
Shield
11
S1-
12
Signal description:
SX+, SX-... Signal lines of the thermocouple interface X (X = 1...4)
Shield ...
Shield potential (connected to functional earth contact of the module)
INFORMATION
An example for the connection of a thermocouple is given on page 17