Open information
DESCRIPTION
28 (69)
Uppgjord (även faktaansvarig om annan) -
Prepared (also subject responsible if other)
Nr
-
No.
KL/ECS/SMK Magnus Lindahl
MRS3000 Programmers reference manual
Dokansv/Godk -
Doc respons/Approved
Kontr
-
Checked
Datum
-
Date
Rev
File
KL/ECS/S/MK
1997-04-16 A
LZB 119 1661
PROG.DOC
PULSE SC TIME (AREA 2 TAB 39)
Value range: 00-FFh, Default 28h (= 40 = 40 ms)
Timebase: 1 ms/10 ms
Short circuit time when dialling with pulses.
Example:
The short circuit time shall be 40 ms.
Table Row Data Comment
39 01 28 40
ms
PULSE PAUSE TIME (AREA 2 TAB 40)
Value range: 00-FFh, Default C1h (= 65 + 80h = 650 ms)
Timebase: 1 ms/10 ms
Pause between digits when dialling with pulses.
Example:
The pause time shall be 650 ms.
Table Row Data Comment
40 01 C1 650
ms
MAX RING BUSY TONES (AREA 2 TAB 41)
Value range: 00-FFh, Default 0Ah (= 10)
The maximum number of consecutive ring- or busy-tones that may be detected when a
telephone call is connected.
Example:
After ten ring- or busy-tones, the call shall be disconnected.
Table Row Data Comment
41
01
0A
10 ring- or busy-tones
RING TONE MIN TIME (AREA 2 TAB 42)
Value range: 00-FFh, Default 50h (= 80 = 800 ms)
Timebase: 10 ms/100 ms
The minimum on-time for the ring tone.
RING TONE EXTRA TIME (AREA 2 TAB 43)
Value range: 00-FFh, Default 94h (= 20 + 80h = 2 s)
Timebase: 10 ms/100 ms
The maximum on-time for the ring tone after RING TONE MIN TIME has expired.
Содержание MRS3000
Страница 143: ......
Страница 144: ......
Страница 145: ......
Страница 146: ......
Страница 147: ......
Страница 148: ......
Страница 149: ......
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 159: ......