Tone Receiver Telegram 17 has following content:
ROW 1:
09
= STAT_ACK, first type of accept-code.
ROW 2:
00
= No action, no second accept-code
ROW 3:
00
= No action, no third accept-code
ROW 4:
00
= The STAT_ACK might be preceded by any tone
ROW 5:
00
= Don't care, no second accept-code in ROW 2
ROW 6:
00
= Don't care, no third accept-code in ROW 3
ROW 7:
0F
= No Bx references to any call number-table
ROW 8:
00
= Normal priority
ROW 9:
00
= First tone is not the last one
ROW 10:
04
= First tones length type 4 (80-120 ms)
ROW 11:
C1
= First tone shall be checked against the first tone saved from last sent call.
ROW 12:
00
= Second tone is not the last one
ROW 13:
04
= Second tones length type 4 (80-120 ms)
ROW 14:
C2
= Second tone shall be checked against the second tone saved from last sent
call.
ROW 15:
00
= Third tone is not the last one
ROW 16:
04
= Third tones length type 4 (80-120 ms)
ROW 17:
C3
= Third tone shall be checked against the third tone saved from last sent call.
ROW 18:
00
= Fourth tone is not the last one
ROW 19:
04
= Fourth tones length type 4 (80-120 ms)
ROW 20:
C4
= Fourth tone shall be checked against the fourth tone saved from last sent call.
ROW 21:
00
= Fifth tone is not the last one
ROW 22:
04
= Fifth tones length type 4 (80-120 ms)
ROW 23:
C5
= Fifth tone shall be checked against the fifth tone saved from last sent call.
ROW 24:
01
= Sixth tone is allowed to be the last one, with accept-type as specified in ROW 1.
ROW 25:
0E
= Sixth tones length type E (minimum 10 ms)
ROW 26:
0F
= Sixth tone-code is F = Pause = No valid CCIR tone.
ROW 27:
03
= Don't care when ROW 29 = FF
ROW 28:
0F
= Don't care when ROW 29 = FF
ROW 29:
FF
= No more tones
ROW 30-56:
Don't care
Tone Receiver Telegram 21 has following content:
ROW 1:
0A
= STAT_1, first type of accept-code.
ROW 2:
00
= No action, no second accept-code
ROW 3:
00
= No action, no third accept-code
ROW 4:
01
= T, S or D might not precede The STAT_1
ROW 5:
00
= Don't care, no second accept-code in ROW 2
ROW 6:
00
= Don't care, no third accept-code in ROW 3
ROW 7:
0F
= No Bx references to any call number-table
ROW 8:
00
= Normal priority
ROW 9:
00
= First tone is not the last one
ROW 10:
02
= First tones length type 2 (10-1500 ms)
ROW 11:
51
= First tone shall be saved as the first status digit.
ROW 12:
00
= Second tone is not the last one
ROW 13:
04
= Second tones length type 4 (80-120 ms)
ROW 14:
52
= Second tone shall be saved as the second status digit.
ROW 15:
01
= Third tone is allowed to be the last one, with accept-type as specified in ROW 1.
Содержание MRS3000
Страница 143: ......
Страница 144: ......
Страница 145: ......
Страница 146: ......
Страница 147: ......
Страница 148: ......
Страница 149: ......
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 159: ......