Open information
DESCRIPTION
32 (69)
Uppgjord (även faktaansvarig om annan) -
Prepared (also subject responsible if other)
Nr
-
No.
KL/ECS/SMK Magnus Lindahl
MRS3000 Programmers reference manual
Dokansv/Godk -
Doc respons/Approved
Kontr
-
Checked
Datum
-
Date
Rev
File
KL/ECS/S/MK
1997-04-16 A
LZB 119 1661
PROG.DOC
LINE VOICE DEB O TIME (AREA 2 TAB 57)
Value range: 00-FFh, Default 2 (= 20 ms)
Timebase: 10 ms/100 ms
The minimum continuous on-time for the line-squelch detector for the radio LF in CU210.
Example:
Line-squelch shall go on after 20 ms with sound.
Table Row Data Comment
57 01 2 20
ms
LINE VOICE DEB OFF TIME (AREA 2 TAB 58)
Value range: 00-FFh, Default 64 (= 1 s)
Timebase: 10 ms/100 ms
The minimum continuous off-time for the line-squelch detector for the radio LF in CU210.
Example:
Line-squelch shall go off after 1 s with no sound.
Table Row Data Comment
58 01 64 1
s
TPH VOICE DEB ON TIME (AREA 2 TAB 59)
Value range: 00-FFh, Default 2 (= 20 ms)
Timebase: 10 ms/100 ms
The minimum continuous on-time for the line-squelch detector for the telephone LF in CU210.
Example:
Line-squelch shall go on after 20 ms with sound.
Table Row Data Comment
59 01 2 20
ms