ALARM CALL TO FIXED TELEPHONE NUMBER
Function digit B
Phone number/destination field content:
0 - 9: Dial corresponding DTMF or pulse digit
A:
Wait for dial tone
B:
Pause. Next digit determines the number of seconds.
C:
Dial DTMF *.
D:
Dial DTMF #.
E: Not
used
Example:
On the received tone sequence 92345 the telephone number "0 - wait for dial tone - 90510" shall
be
dialled.
Addr
Func
Phone
number/dest
92345
B
0A90510
ALARM CALL (STATREQ) TOP CU200S
Function digit C
Phone number/destination field content:
One digit position for each unit called.
Valid destination units are:
0: Unit_CU0, valid only for a CU210 with both control unit- and ADV-functions.
1: Unit_CU1
2: Unit_CU2
3: Unit_CU3
4: Unit_CU4
5: Unit_CU5
6: Unit_CU6
7: Unit_ALL_CUs mustn't be used if an ADV-version CU210 is used in the system.
Example:
The CU with ID number 1 (CU 1) shall be called with the tone sequence 99901.
The CU with ID number 2 (CU 2) shall be called with the tone sequence 99902.
The tone sequence 99900 is a group call to both CU 1 and CU 2.
Addr
Func
Phone
number/dest
99901
C
1
99902
C
2
99900
C
12
Содержание MRS3000
Страница 143: ......
Страница 144: ......
Страница 145: ......
Страница 146: ......
Страница 147: ......
Страница 148: ......
Страница 149: ......
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 159: ......