Open information
DESCRIPTION
35 (69)
Uppgjord (även faktaansvarig om annan) -
Prepared (also subject responsible if other)
Nr
-
No.
KL/ECS/SMK Magnus Lindahl
MRS3000 Programmers reference manual
Dokansv/Godk -
Doc respons/Approved
Kontr
-
Checked
Datum
-
Date
Rev
File
KL/ECS/S/MK
1997-04-16 A
LZB 119 1661
PROG.DOC
TX DEB OFF TIME (AREA 2 TAB 66)
Value range: 00-FFh, Default 4 (= 400 ms)
Timebase: 100 ms/1 s
The time after the telephone LF has silenced until it is regarded as off when speech switching
with VOX is used. From V3.1 of CU210 a 256 ms delay of the LF from the telephone line has
been
added,
This time must be compensated for in this parameter. Setting it to 400 ms will in practice mean
144
ms.
Example:
After telephone LF has been gone for 400 ms, telephone LF shall be shut off and both telephone
and radio voice detect shall be treated equally.
Table Row Data Comment
66 01 04 400
ms
MAX DIAL TONE WAIT TIME (AREA 2 TAB 67)
Value range: 00-FFh, Default 32h (= 50 = 5 s)
Timebase: 100 ms/1 s
The maximum time after the hook has been lifted or having reached a 'wait for dial tone-code in
a pre-programmed telephone number, until the dial tone must have been detected.
Example:
Wait a maximum of 5 seconds for the dial tone.
Table Row Data Comment
67 01 32 5
s
BLOCK TONE ON TIME (AREA 2 TAB 68)
Value range: 00-FFh, Default 19h (= 25 = 250 ms)
Timebase: 10 ms/100 ms
The length of each of the five block tones, transmitted to the telephone line before hanging up.
Содержание MRS3000
Страница 143: ......
Страница 144: ......
Страница 145: ......
Страница 146: ......
Страница 147: ......
Страница 148: ......
Страница 149: ......
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 159: ......