Open information
DESCRIPTION
31 (69)
Uppgjord (även faktaansvarig om annan) -
Prepared (also subject responsible if other)
Nr
-
No.
KL/ECS/SMK Magnus Lindahl
MRS3000 Programmers reference manual
Dokansv/Godk -
Doc respons/Approved
Kontr
-
Checked
Datum
-
Date
Rev
File
KL/ECS/S/MK
1997-04-16 A
LZB 119 1661
PROG.DOC
RING DETECT OF MIN TIME (AREA 2 TAB 53)
The minimum off time for the ring detects.
Value range: 00-FFh, Default 9Eh (= 30 + 80h = 3 s)
Time base: 10 ms/100 ms
RING DETECT OF EXTRA (AREA 2 TAB 54)
Value range: 00-FFh, Default C6h (= 70 + 80H = 7 s)
Timebase: 10 ms/100 ms
The maximum off time for the ring detect after RING DETECT OFF MIN TIME has expired.
Example:
The ring detect must be between 0.28 and 2.28 seconds long.
The pause between the ring detects must be between 3 and 10 seconds.
Table Row Data Comment
51 01 1C Min
280
ms
52
01
94
Max. 280 ms + 2 s = 2.28 s
53 01 9E Min
3
s
54
01
C6
Max. 3 s + 7 s = 10 s
DIAL TONE MIN TIME (AREA 2 TAB 55)
Value range: 00-FFh, Default 94h (= 20 + 80H = 2 s)
Timebase: 10 ms/100 ms
The minimum length of a dial tone.
Example:
The length of the dial tone shall be at least 2 s.
Table Row Data Comment
55 01 94 2
s
DIAL TONE DEB OFF TIME (AREA 2 TAB 56)
Value range: 00-FFh, Default 50h (= 80 ms)
Timebase: 1 ms/10 ms
The maximum length of a pause in the middle of a dial tone.
Example:
The maximum length of a pause in the middle of a dial tone shall be set to 80 ms.
Table Row Data Comment
56 01 50 80
ms
Содержание MRS3000
Страница 143: ......
Страница 144: ......
Страница 145: ......
Страница 146: ......
Страница 147: ......
Страница 148: ......
Страница 149: ......
Страница 150: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......
Страница 154: ......
Страница 155: ......
Страница 156: ......
Страница 157: ......
Страница 159: ......