41
3/1531-ZAP 701 14/1 Uen A 2006-10-16
AXX 9100 CONNECT R1.2 Quick Reference Guide
7.
The system validates the user-id/password and IP address
combination. If valid, i.e. combination correct and valid SNMP
community string, the Craft Terminal sets up a connection to the
specified IP address. The desktop of the Craft Terminal with its
working windows is presented to you.
You can now browse the network element topology and perform the
required management tasks.
2.2.0.2
Non-existent IP-address
The IP-address given by you manually or selected by you in the list,
is not reachable/non-existent or does not belong to an Ericsson
AXXESSIT network element. The system gives an error message
and ask for a new IP-address.
2.3
System mode from IP to IP un-numbered
2.3.1
Products affected
The IP un-numbered feature were introduced in AXX 9100
CONNECT R1.0. This field notice will apply for this and future
releases.
2.3.2
Problem description
Changing system mode from IP (default) to IP un-numbered may
imply problems.
2.3.3
Problem symptoms
Experiences from field (labs) tell us that current implementation
have limitations in software for changing system mode from IP
(default) to IP un-numbered. Even though there are IP addresses
and routing protocols configured on NE the operator does not
receive any notification, which could have prevented the change
until necessary configuration changes have been maintained. From
a software design point-of-view, the configuration of system mode