15
3/1531-ZAP 701 14/1 Uen A 2006-10-16
AXX 9100 CONNECT R1.2 Quick Reference Guide
2.
Insert the stripped end of the grounding wire into the open end of
the female grounding lug.
3.
Use the crimping tool to secure the grounding wire in two different
places in the grounding lug.
4.
Place the male grounding contact against the selected position
(See Figure 5 )
5.
Insert the screw through the locking washer and through the hole
in the male grounding contact.Tighten the screw.
6.
Connect the grounding lug to the male contact.
7.
Prepare the other end of the grounding wire and connect it to an
appropriate grounding point in your site to ensure adequate earth
ground for the shelf.
1.6.3
Install the –AC 230V Power Adaptor
1.6.3.1
Power On
N O T E !
Make sure the AXX 9100 CONNECT is only connected to
mains outlet with safety ground.
Warning!
Insert the DC connector into AXX 9100 CONNECT before
connecting the AC 230V adaptor power cable to mains.
1.
Insert the 4-pin (Molex Mini-fit 4x1) DC connector into the power
connector on the AXX 9100 CONNECT device.
2.
Insert the AC adaptor power cable to mains.