
4-66
OS and Drivers
Rev. I
Windows
The following screen is displayed if the Windows tab is clicked.
Set the detailed items about the Double Click.
❏
[Time]
This sets the time interval to recognize as a double click. The default is 900 ms.
❏
[Height]
This sets the vertical space between the touch positions that will be recognized as a double
click. The default is 64 pixels.
❏
[Width]
This sets the horizontal space between the touch positions that will be recognized as a
double click. The default is 64 pixels.
❏
[Defaults]
This returns each setting item to its original value.
❏
[Mouse Click Test]
This tests the single click and the double click. When the click is done correctly, the face on
the button changes.
Note:
When Windows 2000 is set up and a new user is entered, set the double click latitude to the Default value
(64) for each user. For the details, see the “
The double click setting depends on following the registry
key
” section.
Содержание DM-M820
Страница 1: ...Technical Reference Manual MR Series English 403308709 Rev I EPSON ...
Страница 2: ......
Страница 20: ...xviii Rev I ...
Страница 42: ...2 8 Setup for the IM 800 and the DM M820 Rev I ...
Страница 50: ...3 8 Hardware Specifications Rev I ...
Страница 178: ...5 38 BIOS Functions Rev I ...
Страница 216: ...8 26 Troubleshooting Rev I ...
Страница 270: ...9 54 Disassembly and Assembly Rev I 6 Remove the HDD cable 216 from the Main circuit board HDD cable ...
Страница 323: ......
Страница 324: ...SEIKO EPSON CORPORATION EPSON ...