AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
288
Confidential
9.
Remove the six screws (silver, self-tapping, 10 mm) that secure the DRIVE ASSY MAIN to the main
unit.
10. Remove the DRIVE ASSY MAIN from the main unit.
Kmy03059EA
10)
9)
9)
9)
9)
9)
9)
DRIVE ASSY MAIN
SENSOR ASSY CRU (K)
1.
Remove the screw (silver, self-tapping, 10 mm) that secures the SENSOR ASSY CRU (K) to the
main unit.
2.
Remove the SENSOR ASSY CRU (K) from the main unit.
3.
Disconnect the connector (P/J193) on the SENSOR ASSY CRU (K).
A D
Kmy03035EA
1)
2)
3)
SENSOR ASSY CRU (K)