DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
267
Confidential
PWBA OHP LED
1.
Remove the three screws (silver, self-tapping, 8 mm) that secure the CHUTE ASSY REGI UPPER.
As the CHUTE ASSY REGI UPPER remains connected with a harness, be careful not to
overload the terminal areas of the harness and the connector.
2.
Release the tab on the CHUTE ASSY REGI UPPER, and pull the left side of the CHUTE ASSY
REGI UPPER in the direction of the arrow.
When performing reassembly, pull the harness that is coming out of the right side of the
CHUTE ASSY REGI UPPER slightly to take up the slack out of the harness.
NEXT>>
C
Kmy03213EB
2)-2
2)-1
1)
1)
1)
3.
Remove the two screws (silver, self-tapping, 8 mm) that secure the PWBA OHP LED to the CHUTE
ASSY REGI UPPER.
4.
Disconnect the connector (P/J2412) of the PWBA OHP LED.
Be sure to route the harness as shown in the figure.
4) (J2412)
3)
3)
Kmy03220EB
Tab
Groove
Groove
PWBA OHP LED