AcuLaser C2800/C2800D/C3800/C3800D
Revision C
TROUBLESHOOTING
Engine-related Trouble FIP
105
Confidential
FIP 1-26 Service Req E500 (Motor Failure)
Possible parts that caused the error
Troubleshooting
DRIVE ASSY MAIN
DRIVE ASSY PH
HARNESS ASSY R SIDE
PWBA MCU
Step
Check
Yes
No
1
Check after turning the power OFF and ON.
Does the error recur even when the power is
turned off and back on again?
Go to Step [2].
End of procedure
2
Check the operation of the Main Motor in
the DRIVE ASSY MAIN
Check the Main Motor with reference to
. Was the trouble fixed?
End of procedure Go to Step [3].
3
Check the operation of the Sub Motor in the
DRIVE ASSY MAIN
Check the Sub Motor with reference to
. Was the trouble fixed?
End of procedure Go to Step [4].
4
Check the operation of the Deve Motor in the
DRIVE ASSY MAIN
Check the Deve Motor with reference to
. Was the trouble fixed?
End of procedure Go to Step [5].
5
Check the operation of the DRIVE ASSY PH
Check the DRIVE ASSY PH with reference to
.
---
---