AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
282
Confidential
COVER ASSY FRONT
1.
Press the latch on the COVER ASSY FRONT and open the COVER ASSY FRONT.
A B
C D
1) -1
1) -2
LATCH
COVER ASSY FRONT
FUSER UNIT
Be careful not to burn yourself as the FUSER section remains at high temperature after
turning the power off.
1.
Open the CHUTE DUP GATE.
2.
Rotate the levers on the left and right side of the FUSER UNIT as shown in the direction of the arrow,
and unlock the lock.
3.
Slide the FUSER UNIT toward front of the printer, release the connector and the guide pin from the
main unit, and remove the FUSER UNIT by lifting it straight up.
A B
C D
Kmy03046EA
1)
2)
2)
3)
FUSER UNIT
Содержание AcuLaser C2800D
Страница 13: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 30: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 76: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 159: ...Confidential C H A P T E R 4 DISASSEMBLY REASSEMBLY ...
Страница 381: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 389: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 395: ...Confidential C H A P T E R 7 APPENDIX ...