AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
341
Confidential
PWBA USB
1.
Disconnect the connector (CN2) of the PWBA USB.
2.
Remove the two screws (silver, 6 mm) that secure the PWBA USB to the main unit.
3.
Remove the PWBA USB from the main unit.
B
Kmy03063EA
1)
2)
2)
3)
PWBA USB
SWITCH POWER
1.
Disconnect connector (P/J481) of the SWITCH POWER.
2.
Release the tabs of the SWITCH POWER and remove the SWITCH POWER from the main unit.
Mind the correct orientation when installing the SWITCH POWER.
Match the ON/OFF of the SWITCH POWER with that engraved on the BRACKET SW
E surface.
C
Kmy03070EB
1)
2)-1
2)-1
2)-2
SWITCH POWER