Confidential
5.2.3 Writing USB ID
PURPOSE
AcuLaser C2800/C2800D/C3800/C3800D comes with the USB interface as a
standard, and the computer connected to the AcuLaser C2800/C2800D/C3800/
C3800D via the USB interface identifies the printer by referring to the USB ID
information unique to each printer.
Since this USB ID information is stored on EEPROM on the main board of the printer,
you have to re-define the ID information by following the procedure described below
after replacing the main board for repair.
TOOL
The program required for writing USB ID and the system requirements are as follows:
Program
PPInitSetting_Ver1x E.exe
System requirements
OS:
Windows 95/98/ME/2000/XP
Port used: LPT, USB
INSTALLATION AND THE OPERATION OF THE PROGRAM
1)
Copy all the files related to “PPInitSetting” program and save them into one
folder.
2)
Double-click the program icon [
] to start the program.
3)
Select the model name from [Model Selection].
4)
Select the port used to connect the printer from [Port Selection].
Figure 5-2. Operation of the Program
C H E C K
P O I N T
Be sure to save a complete set of files related to “PPInitSetting”
program into one folder.
C H E C K
P O I N T
When you select “Auto selection”, the computer automatically
detects the connected printers and starts communicating with the
one detected first. When two or more printers are connected,
specify the target port to avoid unexpected connection.
Содержание AcuLaser C2800D
Страница 13: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 30: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 76: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 159: ...Confidential C H A P T E R 4 DISASSEMBLY REASSEMBLY ...
Страница 381: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 389: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 395: ...Confidential C H A P T E R 7 APPENDIX ...