AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
366
Confidential
COVER RIGHT
1.
Remove the four screws (silver, brimmed, 8 mm) that secure the COVER RIGHT to the FRAME
ASSY OPT.
2.
Pull the protrusion of the COVER RIGHT out of the concave surface of the FRAME ASSY OPT,
and remove the COVER RIGHT.
A B
C
Kmy03235EA
1)
1)
1)
1)
2)
COVER RIGHT
CLUTCH ASSY TURN OPT
1.
Disconnect the connector (P/J4201) on the harness of the CLUTCH ASSY TURN OPT.
2.
Loosen the three clamps that secure the harness of the CLUTCH ASSY TURN OPT, and remove the
harness.
3.
Remove the KL-ring that secures the CLUTCH ASSY TURN OPT to the ROLL ASSY TURN.
4.
Remove the CLUTCH ASSY TURN OPT from the ROLL ASSY TURN.
A B
C
Kmy03233E
B
2)
3)
4)
2)
2)
1) (J4201)