AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
216
Confidential
v
ROLL ASSY RETARD
1.
Remove the SPRING RETARD that is attached to the HOLDER RETARD MSI.
2.
With the BEARING RETARD R, L attached to the ROLL ASSY RETARD, remove the BEARING
RETARD R, L from the groove of the HOLDER RETARD MSI.
3.
Remove the BEARING RETARD R, L from the ROLL ASSY RETARD.
C
Kmy03201EA
1)
1)
2)
2)
3)
ROLL ASSY RETARD
PLATE ASSY BOTTOM
1.
Remove the SPRING NF MSI hitched on the ARM L, R.
2.
Remove the screw (silver, 6 mm) that secures the HOLDER ASSY MSI L to the PLATE ASSY
BOTTOM, and remove the HOLDER ASSY MSI L.
3.
While lifting up the ACTUATOR NO PAPER MSI, remove the PLATE ASSY BOTTOM from the
HOUSING BASE FR 550.
D
Kmy03202EA
2)-1
2)-2
1)
3)-1
3)-2
1)
PLATE ASSY BOTTOM