AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
294
Confidential
3.
Remove the four screws (silver, self-tapping, 10 mm) that secure the two SPRING ROSes to the main unit.
4.
Remove the two SPRING ROSes from the main unit.
5.
Hold the handle of the ROS ASSY, and pull it straight up to remove from the main unit.
Kmy03033EA
3)
4)
4)
5)
3)
3)
3)
Handle
ROS ASSY
HVPS
Do not remove/install the board in areas where static sparks may be generated.
(e.g. on a carpet) Be sure to touch a metal part to discharge any static electricity you might
have before removing/installing the board.
1.
Disconnect connector of the HVPS (P/J16) on the PWBA MCU, and pull out the connector through
the hole in the SHIELD MCU.
NEXT>>
C
Kmy03042EA
1)-1
1)-2
Содержание AcuLaser C2800D
Страница 13: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 30: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 76: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 159: ...Confidential C H A P T E R 4 DISASSEMBLY REASSEMBLY ...
Страница 381: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 389: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 395: ...Confidential C H A P T E R 7 APPENDIX ...