AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
236
Confidential
CLUTCH ASSY PH FEED
C H E C K
P O I N T
The mid connector should remain connected to the main unit.
1.
Disconnect the connector (P/J235) of the CLUTCH ASSY PH FEED.
Match the colors of the harnesses of the clutches with that of the harnesses of the main unit.
2.
Release the harness (yellow) of the CLUTCH ASSY PH FEED from the clamp and the tab on the
main unit frame.
3.
Remove the E-ring that secures the CLUTCH ASSY PH FEED to the FEEDER ASSY.
4.
Remove the CLUTCH ASSY PH FEED from the FEEDER ASSY.
Do not misplace the CLUTCH ASSY PH REGI and the CLUTCH ASSY PH FEED. When
installing the clutches, match the colors of the harnesses and the positioning ribs of the
clutches.
Color of the CLUTCH ASSY PH REGI harness is gray.
Color of the CLUTCH ASSY PH FEED harness is yellow.
A C
Kmy03025EB
1)
2)
2)
3)
4)
Yellow
Yellow
Yellow
CLUTCH ASSY PH FEED
FEEDER ASSY
C H E C K
P O I N T
It is not necessary to remove the SENSOR PHOTO:MSI NO PAPER and the COVER SNR
when performing the following work.
1.
Remove the two screws (silver, self-tapping, 10 mm) that secure the CHUTE MSI to the main unit.
Do not pull the CHUTE MSI from the main unit too far as they are connected with a
harness.
2.
Remove the CHUTE MSI from the main unit.
Be careful not to pinch the cable between the CHUTE MSI and the main unit.
NEXT>>
A
Kmy03026EA
1)
1)
2)
Содержание AcuLaser C2800D
Страница 13: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 30: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 76: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 159: ...Confidential C H A P T E R 4 DISASSEMBLY REASSEMBLY ...
Страница 381: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 389: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 395: ...Confidential C H A P T E R 7 APPENDIX ...