AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
299
Confidential
COVER ASSY FRONT
1.
Press the latch on the COVER ASSY FRONT and open the COVER ASSY FRONT.
A B
C
1) -1
1) -2
LATCH
COVER ASSY FRONT
CHUTE ASSY EXIT OUT
1.
Remove the two screws (silver, brimmed, self-tapping, 10 mm) that secure the CHUTE ASSY EXIT
OUT to the COVER ASSY FRONT.
2.
Remove the CHUTE ASSY EXIT OUT from the COVER ASSY FRONT.
A
Kmy03045EA
1)
1)
2)
CHUTE ASSY EXIT OUT
Содержание AcuLaser C2800D