AcuLaser C2800/C2800D/C3800/C3800D
Revision C
TROUBLESHOOTING
Abnormal Noise-related Trouble
152
Confidential
3.6.2 Abnormal Noise-related FIP
FIP-N1 AT POWER ON
Possible parts that caused the error
Troubleshooting
FIP-N2 DURING STANDBY
Possible parts that caused the error
Troubleshooting
DRIVE ASSY MAIN
FUSER UNIT
IMAGING CARTRIDGE (Y/M/C/K)
TRANSFER UNIT
FEEDER ASSY DUP
Step
Check
Yes
No
1
Is abnormal noise being
generated by the DRIVE ASSY
MAIN?
Reinstall the DRIVE
ASSY MAIN. When the
trouble still occurs,
replace the DRIVE
ASSY MAIN.
Go to Step [2].
2
Is abnormal noise being
generated by the FUSER UNIT?
Reinstall the FUSER
UNIT.
When the trouble still
occurs, replace the
FUSER UNIT.
Go to Step [3].
3
Is abnormal noise being
generated by the IMAGING
CARTRIDGE (Y/M/C/K)?
Reinstall the IMAGING
CARTRIDGE (Y/M/C/
K). When the trouble still
occurs, replace the
IMAGING
CARTRIDGE (Y/M/C/
K).
Go to Step [4].
Step
Check
Yes
No
4
Is abnormal noise being
generated by the TRANSFER
UNIT?
Reinstall the
TRANSFER UNIT.
When the trouble still
occurs, replace the
TRANSFER UNIT.
Go to Step [5].
5
Is abnormal noise being
generated by the FEEDER ASSY
DUP?
Reinstall the FEEDER
ASSY DUP. When the
trouble still occurs,
replace the FEEDER
ASSY DUP.
---
FAN MAIN
LVPS
Step
Check
Yes
No
1
Is abnormal noise being
generated by the FAN MAIN?
Reinstall the FAN
MAIN. When the trouble
still occurs, replace the
FAN MAIN.
Go to Step [2].
2
Is abnormal noise being
generated by the LVPS?
Replace the LVPS.
---
Содержание AcuLaser C2800D
Страница 13: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 30: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 76: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 159: ...Confidential C H A P T E R 4 DISASSEMBLY REASSEMBLY ...
Страница 381: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 389: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 395: ...Confidential C H A P T E R 7 APPENDIX ...