TROUBLESHOOTING
Engine-related Trouble FIP
107
Confidential
FIP 1-28 Service Req E600 (ADC Sensor Error)
Possible parts that caused the error
Troubleshooting
TRANSFER UNIT
PWBA MCU
HARNESS ASSY FRONT COVER
HARNESS ASSY R SIDE
Step
Check
Yes
No
1
Check after turning the power OFF and ON.
Does the error recur even when the power is
turned off and back on again?
Go to Step [2].
End of procedure
2
Check the installation of the TRANSFER
UNIT
Is the TRANSFER UNIT installed correctly?
Go to Step [3].
Reinstall the
TRANSFER
UNIT correctly.
3
Check the connection of the TRANSFER
UNIT
Check the connection state between
TRANSFER UNIT and PWBA MCU.
Are P/J2721, P/J272, and P/J27 connected
correctly?
Go to Step [4].
Reconnect the
P/J2721, P/J272,
and P/J27
correctly.
4
Check the continuity of the HARNESS ASSY
FRONT COVER
Is the continuity between P/J2721 <=> P/J272
normal?
Go to Step [5].
Replace the
HARNESS
ASSY FRONT
COVER.
5
Check the continuity of the HARNESS ASSY
R SIDE
Is the continuity between P/J27 <=> P/J272
normal?
Go to Step [6].
Replace the
HARNESS
ASSY R SIDE.
6
Check the power voltage supply to the ADC
Sensor in the TRANSFER UNIT.
Measure the voltage between PWBA MCU
ground <=> P/J27-A7PIN.
Is the power voltage (approx. +5 V) output?
Replace the
TRANSFER
UNIT.
Replace the
PWBA MCU.
Содержание AcuLaser C2800D
Страница 13: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 30: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 76: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 159: ...Confidential C H A P T E R 4 DISASSEMBLY REASSEMBLY ...
Страница 381: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 389: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 395: ...Confidential C H A P T E R 7 APPENDIX ...