AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
274
Confidential
COVER REAR
1.
Remove the four screws (silver, self-tapping, 10 mm) that secure the COVER REAR to the main unit.
2.
Remove the COVER REAR from the main unit.
A C D
1)
1)
1)
1)
2)
Kmy03003EA
COVER REAR
COVER SIDE L
As the FUSER UNIT remains at hazardous temperature after turning the power off, be
careful not to burn yourself.
1.
Release the lock on the left side of the FUSER UNIT.
2.
Remove the three screws (silver, self-tapping, 10 mm) that secure the COVER SIDE L to the main unit.
3.
Pull the COVER SIDE L so that it comes free from the two protrusions of the main unit.
4.
Release the two tabs on the back side and the two tabs on the front side of the COVER SIDE L, and
remove the COVER SIDE L from the main unit.
A D
Kmy03006EA
2)
1)
2)
2)
3)
3)
4)-1
4)-1
4)-1
4)-1
4)-2
COVER SIDE L
Содержание AcuLaser C2800D
Страница 13: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 30: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 76: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 159: ...Confidential C H A P T E R 4 DISASSEMBLY REASSEMBLY ...
Страница 381: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 389: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 395: ...Confidential C H A P T E R 7 APPENDIX ...