AcuLaser C2800/C2800D/C3800/C3800D
Revision C
TROUBLESHOOTING
Engine-related Trouble FIP
119
Confidential
FIP 1-48 Wrong Toner Cyan(C)
Possible parts that caused the error
Troubleshooting
FIP 1-49 Wrong Toner Black(K)
Possible parts that caused the error
Troubleshooting
IMAGING CARTRIDGE (C)
PWBA MCU
Step
Check
Yes
No
1
Check the installation position
Is the IMAGING CARTRIDGE (C) installed in
the correct position?
Go to Step [2].
Install the
IMAGING
CARTRIDGE (C)
in the correct
position.
2
Check after replacing the IMAGING
CARTRIDGE (C)
Replace the IMAGING CARTRIDGE (C) with
a new one.
Does the error still occur after the replacement?
Replace the
PWBA MCU.
End of procedure
IMAGING CARTRIDGE (K)
PWBA MCU
Step
Check
Yes
No
1
Check the installation position
Is the IMAGING CARTRIDGE (K) installed in
the correct position?
Go to Step [2].
Install the
IMAGING
CARTRIDGE
(K) in the correct
position.
2
Check after replacing the IMAGING
CARTRIDGE (K)
Replace the IMAGING CARTRIDGE (K) with
a new one.
Does the error still occur after the replacement?
Replace the
PWBA MCU.
End of procedure
Содержание AcuLaser C2800D
Страница 13: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 30: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 76: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 159: ...Confidential C H A P T E R 4 DISASSEMBLY REASSEMBLY ...
Страница 381: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 389: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 395: ...Confidential C H A P T E R 7 APPENDIX ...