• CO2 Tickle Holdoff [us]
• The duration in which the laser tickle is stalled after a laser pulse in microseconds
• CO2 Pulse Stretch [us]
• The amount to stretch all laser pulses in microseconds
• Table Focus Offset [cnts]
• The distance in table encoder counts from the top crash switch, to the laser focus position
• RHS Y Skew [cnts]
• The number of encoder counts to skew the right hand side of the Y axis after homing
• Requires “Home Axis” to take effect
• Air Assist Delay [s]
• The number of seconds to delay turning ON and turning OFF the air assist before and after a job
finished
• Format is as follows: ON,OFF
- 135 -